Micro‑air‑consumption, blow‑in‑air, heat‑regenerated adsorption dryer
E-mail:
bibetterchina@yeah.net
- 产品描述
-
Product Description
The processing capacity ranges from 11 to 120 Nm³/min. This product series is precisely tailored to meet user needs, featuring an ultra‑efficient energy‑saving design that maintains a dew point of –40°C while utilizing ambient air throughout the regeneration process, with no compressed‑air consumption.
Blow‑in, zero‑air‑consumption adsorption dryer featuring a large‑diameter tower design and high‑efficiency adsorbent packing to ensure stable dew point performance. Equipped with premium components and multiple safety safeguards for reliable operation, it also incorporates a sophisticated control system with an LCD display and temperature‑based control to optimize operating costs.
Operating conditions
Maximum intake air temperature
45℃
Oil content of intake air
≤0.1 ppm
Pressure range
0.6~1.0 MPa
Control method
PLC
Pressure dew point
≤-40℃
Control power supply
AC 380V/50HZ
Pressure loss
≤3% of the design pressure
Cycle
T=8h
Regeneration gas consumption
≤2-3%
Note: Other special standards can be customized.
Model number
Processing capacity Nm³/min
Voltage
Air inlet and outlet pipe diameter
External dimensions (mm): Length × Width × Height HDLB-110
11
380V
DN50
1490x800x2140
HDLB-140
14
380V
DN50
1490x800x2140
HDLB-180
18
380V
DN65
1650x850x2430
HDLB-220
22
380V
DN65
1650x850x2430
HDLB-280
28
380V
DN 80
1860x900x2590
HDLB-320
32
380V
DN 80
1860x900x2590
HDLB-380
38
380V
DN100
2170x1000x2680
HDLB-450
45
380V
DN100
2170x1000x2680
HDLB-520
52
380V
DN125
2280x1600x2750
HDLB-600
60
380V
DN125
2280x1600x2750
HDLB-720
72
380V
DN125
2490x1750x2910
HDLB-800
80
380V
DN125
2490x1750x2910
HDLB-1000
100
380V
DN150
2690x1800x2970
HDLB-1200
120
380V
DN150
2850x1850x3020
Note: In the event of changes to the model, specifications, or color, the actual product shall prevail; the above parameters are for reference only. Customization is available for special models. BIBETTER (Shanghai) Purification Technology Co., Ltd. reserves the right of final interpretation.
Correction factor
Working pressure (barG)
4.5
5
6
7
8
9
10
Correction factor
0.670
0.740
0.870
1.000
1.100
1.210
1.330
Standard configuration
- Pressure dew point: -40°C
- High-quality adsorbent
- PLC control
- Dew Point Display and Energy-Saving Module
- Valve Position Control
- Double-eccentric hard-sealed butterfly valve
- Tower insulation
Optional configuration
- Pressure dew point: -70°C
- Hot-dip galvanized and stainless steel pipes
- Dew Point Control
- Variable-frequency blower
- Special Pressure
- Special Power Supply Conditions
- High-temperature, high-pressure intake air
Micro‑air‑consumption, blow‑in‑air, heat‑regenerated adsorption dryer
E-mail:
bibetterchina@yeah.net
Category:
Consult Now
We will call you within 3 business days. Please ensure your phone is reachable.